  • Aerobic capacity: the maximum amount of oxygen the body can utilize during intense physical effort.

Introduction

Aerobic capacity, commonly expressed as maximal oxygen uptake (VO2max), is a determining factor in performance across a wide range of sports ranging from endurance disciplines to intermittent team sports that rely on repeated high-intensity efforts with varying periods of recovery. Because VO2max reflects the integrated capacity of the cardiovascular, respiratory, and muscular systems to deliver and use oxygen, it is frequently used as a marker of aerobic fitness as well as a tool to monitor training adaptations over time.

Direct measurement of VO2max requires a graded exercise test on a treadmill or cycle ergometer with metabolic gas analysis. Although this method is considered to be the gold standard of testing aerobic capacity, it is also expensive, time-consuming, and impractical for testing large pools of athletes. This has led the development of indirect field tests that estimate aerobic capacity from performance outcomes rather than direct gas exchange measurement. Among these, the 20m shuttle run test (also known as the multistage fitness test, PACER, or beep test) is one of the most widely used in sport science and physical education. This is mainly because it can be administered to large groups simultaneously, while requiring minimal equipment. It also correlates reasonably well with directly measured VO2max.

This post explains how to administer the 20m shuttle run test, also known as the PACER test, and how to use the results for long-term tracking.

The basics of the PACER test

The PACER (Progressive Aerobic Cardiovascular Endurance Run) test is based on the original 20m shuttle run test developed by Léger and Lambert and later validated in its most widely cited form in 1988. The study also established regression equations for estimating VO₂max from shuttle-run performance, which have been widely applied in children, adolescents, and adults. The standard protocol consists of continuous 60s stages with progressively increasing running speeds.

The reliability of the PACER test has initially been reported as good, with test-retest coefficients around 0.89 in children and 0.95 in adults in the original validation work. Subsequent studies, however, challenged Léger’s prediction equations in different populations. Most notably, several validation studies conducted with young adults found that the original Léger equations systematically underpredicted VO2max compared to treadmill-measured values. This resulted in the development of alternative equations, such as Léger and Gadoury, St Clair-Gibson, and Ramsbottom and Flouris equations. The latter produced estimates closer to those derived from treadmill tests in that population, while the former equations tended to overestimate VO2max. This inconsistency across studies highlights an important limitation of the test: prediction equations are population-specific, and applying an equation derived from one age group, sex, or sport to a different population can introduce systematic bias in either direction. Practitioners should therefore be cautious about treating any single equation as universally valid, and ideally select an equation validated on a comparable population, or use the raw result (i.e. final stage or number of shuttles completed) as a relative performance indicator rather than converting it to an absolute VO2max value.

Because the test also depends on pacing ability, motivation, running economy, and turning technique at each 20m mark, individual results may be influenced by factors unrelated to aerobic capacity itself. This is a relevant consideration when comparing individuals or interpreting change over time, particularly in younger or less experienced subjects.

Share this post

The PACER Test (20m Shuttle Run Test)


Subjects run a 20m distance back-and-forth while listening to an audio recording.At the sound of the beep, the subject must have one foot on or beyond the line before running back to the opposite line.The initial running speed is 8.5 km/h (~5.3mph), and increases by 0.5 km/h (~0.3mph) approximately every minute. Each increment referred to as a level or stage.As the pace increases, less time is available between beeps.If a subject arrives at the line before the beep, they must wait for the signal before continuing.The test ends for an individual when they can no longer keep pace with the audio signal.The final completed level and shuttle number are recorded.

Equipment needed

To conduct the 20m shuttle run test, the following equipment is required:

  • Flat, non-slip surface of at least 20m in length.
  • Two marker cones or lines, placed exactly 20m apart.
  • Audio recording of the PACER shuttle run test protocol (progressively decreasing intervals between beeps) or a stopwatch with the stage timing table.
  • Speaker system loud enough for all subjects to hear clearly.
  • Measuring tape (to confirm the 20m distance accurately)
  • Note: an inaccurate 20m distance meaningfully affects the validity of the outcome, since the pacing of the audio signal is calibrated to that exact distance. Surfaces that are slippery or uneven can also affect turning speed and should be avoided where possible.

Conducting the test

As with most physical performance assessments, the test should be preceded by a brief dynamic warmup. This should take approximately 5-10 minutes and include light jogging and dynamic stretching of the lower extremities, followed by a small number of practice shuttles so subjects become familiar with the turning technique and pacing demands before the test begins.

  • Set two cones exactly 20m apart on a flat surface. More cones can be added if the test is administered for several people simultaneously.
  • Prepare the audio recording or timing protocol. Make sure the audio is tested for volume and clarity before subjects begin. 
  • Subjects are positioned behind one of the two lines, facing the opposite line.
  • Subjects run from one line to the other, timed to arrive at the far line in time with an audio beep. 
  • At the sound of the beep, the subject must have one foot on or beyond the line before turning and running back to the opposite line for the next beep. 
  • The initial running speed is 8.5 km/h (~5.3mph), and increases by 0.5 km/h (~0.3mph) approximately every minute. Each increment referred to as a level or stage.
  • As the pace increases, less time is available between beeps, which requires subjects to progressively increase their running speed. 
  • If a subject arrives at the line before the beep, they must wait for the signal before continuing. 
  • The test ends for an individual when they can no longer keep pace with the audio signal. This is traditionally defined as failing to reach the line within roughly two meters (6.6ft) of the beep on two consecutive occasions.
  • The final completed level and shuttle number are recorded, since these values are used in the prediction equations.
  • Note: because the test is maximal and pacing-dependent, clear and consistent instructions, along with verbal encouragement standardised across all subjects, are important to reduce variability introduced by motivation and pacing strategy rather than true aerobic capacity.

If VO2max is estimated from the outcome, one of the following formulas can be used:

  • The Léger et al. (1988) equation for youth: VO2max (ml/kg/min) = 31.025 + 3.238X − 3.248A + 0.1536AX, where X is the running speed (km/h) at the final completed stage and A is age in years. Note: the chart below showing age-specific percentiles also uses this equation. 
  • The Léger and Lambert (1982) equation for adults: VO2max (ml/kg/min) =  5.857 x V − 19.458, where V is the final running speed (km/h) achieved on the 20m shuttle run.
  • The Mahar (2011) equation for youth: VO2max (ml/kg/min) = 40.345 + 0.214 (PACER laps) + 4.273 (gender) + 0.794 (age) − 0.795 (BMI), where gender = 1 for boys and 0 for girls.
  • The Ramsbottom et al. (1988) equation for adults: VO2max (ml/kg/min) = 14.4 + 3.48X, where X is final shuttle level attained (effectively speed) on the 20m SRT.

Once the test has been accurately conducted, the results can be compared to the international percentiles per age and gender:

Interpreting the results

The raw outcome of the PACER test (the final completed level and shuttle number) is the most reliable piece of information produced and should be the primary value recorded. Converting this into an estimated VO2max adds another layer of measurement error on top of the test’s own variability. Therefore, any suggested VO2max figure should be treated as an estimate with a meaningful margin of error rather than a precise physiological value, particularly given the conflicting over- and underestimation patterns mentioned above. 

For between-individual comparisons, results are typically interpreted against normative or percentile reference data specific to age and sex, when available. These norms differ by population and country, so imported reference tables should be used with caution outside the population they were derived from. For within-individual, repeated-testing use, which is arguably the more defensible application in a training context, the relevant question is whether a change in performance across testing sessions reflects a real change in aerobic capacity or simply the variability between two different tests. This requires knowledge of the test’s typical error (from test-retest studies) relative to the smallest change considered practically meaningful for the athlete or group. A change smaller than the typical error cannot be confidently interpreted as a true change, regardless of the direction it points. Non-physiological factors, such as pacing strategy, motivation, familiarity with the turning technique, and surface conditions, should also be considered before attributing a change in score to a change in aerobic fitness.

The Best Sports Science eBooks Available.

Forget about overpriced online courses and expensive tuition fees. Our eBooks offer everything you need to know about athletic training.

Final thoughts

The PACER test, also known as the 20m shuttle run test, remains one of the most practical and widely used field tests to estimate aerobic capacity, particularly in settings where testing large groups with limited equipment is a priority. 

Its main strength lies in its logistical simplicity and relatively strong correlation with directly measured VO2max in several validation studies. Its main limitation lies in the variability of prediction accuracy across different populations, with studies reporting both systematic underestimation and overestimation depending on the equation and sample used. For this reason, the test is best used with some caution when absolute VO2max values are required. The PACER test is arguably more defensible as a relative measure for tracking change within the same individual or group over time, or for ranking individuals within a comparable population, than as a precise estimate of true VO2max. When higher measurement precision is required, direct laboratory testing remains the reference standard. Other field-based alternatives such as the Yo-Yo Intermittent Recovery Test offer a protocol that is more specific to the intermittent demands of team sports.

Did you learn anything new about the PACER, or 20m shuttle run, test? Let us know in the comments.

Bibliography

  • Léger LA, Lambert J. A maximal multistage 20-m shuttle run test to predict VO2 max. Eur J Appl Physiol Occup Physiol. 1982;49(1):1-12. doi: 10.1007/BF00428958. PMID: 7201922.
  • Léger, L. A., Mercier, D., Gadoury, C., & Lambert, J. (1988). The multistage 20 metre shuttle run test for aerobic fitness. Journal of Sports Sciences, 6(2), 93-101.
  • Léger L, Gadoury C. Validity of the 20 m shuttle run test with 1 min stages to predict VO2max in adults. Can J Sport Sci. 1989 Mar;14(1):21-6. PMID: 2924218.
  • Magee, M. K., White, J. B., Merrigan, J. J., & Jones, M. T. (2021). Does the multistage 20-m shuttle run test accurately predict VO2max in NCAA Division I women collegiate field hockey athletes? Sports, 9(6), 75.
  • Mahar, M.T., Guerieri, A.M., Hanna, M.S., & Kemble, C.D. (2011). Estimation of aerobic fitness from 20-m multistage shuttle run test performance. American Journal of Preventive Medicine, 41(4S2), S117-S123.
  • Migliano P, Kabiri LS, Cross M, Butcher A, Frugé A, Brewer W, Ortiz A. Validation of Cardiorespiratory Fitness Measurements in Adolescents. J Funct Morphol Kinesiol. 2019 Jul 13;4(3):44. doi: 10.3390/jfmk4030044. PMID: 33467359; PMCID: PMC7739358.
  • Ramsbottom R, Brewer J, Williams C. A progressive shuttle run test to estimate maximal oxygen uptake. Br J Sports Med. 1988 Dec;22(4):141-4. doi: 10.1136/bjsm.22.4.141. PMID: 3228681; PMCID: PMC1478728.
  • Ramsbottom R, Nevill AM Plowman SA (2022) Validation of an Allometric Model to Predict Cardiorespiratory Fitness in Young adults from 20-M Shuttle Run Test Performance. Int J Sports Exerc Med 8:226. doi.org/10.23937/2469-5718/1510226.
  • Tomkinson GR, Lang JJ, Tremblay MS, Dale M, LeBlanc AG, Belanger K, Ortega FB, Léger L. International normative 20 m shuttle run values from 1 142 026 children and youth representing 50 countries. Br J Sports Med. 2017 Nov;51(21):1545-1554. doi: 10.1136/bjsports-2016-095987. Epub 2016 May 20. PMID: 27208067.

Join our growing list of subscribers!

Stay informed about the latest in sports science and physical performance. Subscribe to our mailing list for the latest updates, posts, products and much more.


    Daniel Kiikka

    Daniel Kiikka holds a Master’s Degree in sports science, with a focus on sports pedagogy. After graduating from the University of Jyväskylä in 2015, Daniel worked nearly a decade within the world-renowned Finnish educational system as a physical education and health science teacher. Since 2021, Daniel has worked as a Lecturer at the Amsterdam University of Applied Sciences.