• Introduction
  • The basics of the countermovement jump test
  • Equipment needed
  • Conducting the test
  • Interpreting the results 
  • Final thoughts
  • Bibliography
  • Impulse-momentum relationship: the impulse applied to an object is equal to the change in its momentum.
  • Rate of Force Development: the speed at which your muscles can generate force.
  • Reactive strength: the neuromuscular system’s ability to rapidly produce high force output when transitioning from eccentric to concentric muscle action.
  • The muscle-tendon unit: the connection between the muscles and tendons, through which contractile forces are generated and transmitted.
  • The stretch-shortening cycle: a muscle is first actively stretched before it actively shortens, producing greater force output.

Introduction

Neuromuscular power (the capacity to produce force rapidly) is a key component in a large proportion of movements in found in traditional sports. These include actions such as jumping, kicking, sprinting, striking, and rapid changes in direction. Power output (force multiplied by velocity) and rate of force development (the speed at which force is generated) are both expressions of neuromuscular capability. However, the two capture different aspects of it and depend on the interaction between the nervous system and the muscle-tendon unit. This interaction changes quickly in response to training, fatigue, and recovery, making it particularly interesting to coaches and sport scientists looking for quick assessments of an athlete’s neuromuscular status. 

The countermovement jump (CMJ) has become the default field test in strength and conditioning, rehabilitation, and athlete monitoring. Direct assessment of the mechanical output of a jump requires a force platform, which records the ground reaction force the athlete produces throughout the entire movement. Jump height is then calculated through the impulse-momentum relationship (the impulse applied to an object is equal to the change in its momentum). Because this method tracks force continuously rather than measuring jump height from time spent airborne, it does not depend on the subject adopting the same body position at take-off and landing. It is therefore considered a reference standard that other lower-extremity power assessment methods are compared to. 

However, force platforms are relatively expensive and less portable than simpler field alternatives, which has led to the widespread use of cheaper devices such as contact mats, linear position transducers, and smartphone applications. These methods do not all work the same way. Contact mats and most smartphone applications estimate jump height from flight time, whereas linear position transducers utilize a cord attached to the athlete. When the subject jumps, the cord unspools, and the resulting displacement and velocity data are used to calculate jump height directly.

The CMJ protocol has stayed remarkably consistent since Asmussen and Bonde-Petersen’s (1974) foundational work on the storage of elastic energy in skeletal muscle. The study established the stretch-shortening cycle as the mechanism underlying the countermovement’s performance benefit. What has changed since then is the technology available (e.g., basic timing gates, force platforms, linear position transducers, markerless motion capture, etc.) to measure the outcome of the CMJ test. This evolution in measurement approach should also be kept in mind when interpreting the results, as different devices can produce meaningfully different results for the same jump. This post explains how to successfully conduct the countermovement jump test and how to use the results for athlete monitoring and long-term tracking.

The basics of the countermovement jump test

The countermovement jump consists of a rapid downward movement (the eccentric phase) immediately followed by a maximal vertical jump (the concentric phase), with no pause in between. This eccentric-concentric coupling engages the stretch-shortening cycle, which allows for greater force and power output when compared to a jump from a static squat position. Due to its dynamic nature, the CMJ also closely resembles the performance demands found in real-life sports settings.

The countermovement jump test was used in early biomechanical work by Asmussen and Bonde-Petersen (1974) to measure the contribution of stored elastic energy to jumping performance. The CMJ was later popularized as a practical field test by Bosco, Luhtanen, and Komi (1983) who described a method for estimating mechanical power in jumping from flight time during a repeated rebound jumping test. This flight-time based approach to power estimation was later adapted into the single-trial CMJ field protocol now in widespread use.The most common execution protocol involves a standing start with feet approximately shoulder-width apart, a self-selected or standardized countermovement depth, as well as a takeoff and landing in the same location with legs extended in the air. A key methodological choice is whether the arms are allowed to swing freely or be fixed on the hips throughout the movement. 

Both the countermovement and the arm swing significantly increase jump height, but the arm swing contributes more than the countermovement itself. This is because the arm swing raises the center of mass further during push-off and increases ground reaction force in the latter half of the propulsive phase. The reported increases in jump height with an arm swing typically ranges approximately 10% to 30% depending on the jump type and study, which means that the two variants (with and without arm swing) are not interchangeable and should not be compared directly against one another or against different normative datasets. If the goal is to isolate lower body power, it is best to keep hands on hips.

Countermovement depth is another variable that is often left unstandardized. Despite the test’s widespread use, no universal agreement exists regarding the optimal depth of the lowering phase of the countermovement jump. Because depth affects both the loading of the stretch-shortening cycle and the resulting force output, practitioners are generally advised to choose a single protocol and hold it constant within an athlete or squad, rather than searching for a universally optimal depth.

Share this post

The Countermovement Jump Test


Subjects perform a countermovement jump with hands on their hips, using self-selected squat depth.The subjects jump as high as possible in one continuous motion. The legs should remain extended in the air and the subject should land in approximately the same location as take-off.An average of max. three countermovement jumps is calculated.The result can be assessed using contact mats, linear position transducers, and smartphone applications.Different formulas can be used to calculate flight time or power output.

Equipment needed

To successfully conduct a countermovement jump test, one of the following measurement systems is required. Note: these are in order from most to valid to least valid:

  • A force platform that measures ground reaction force directly and calculates jump height using the impulse-momentum method. This is the reference standard. Also able to measure rate of force development, braking and propulsive impulse, and reactive strength index modified (RSImod).
  • A contact mat that estimates jump height using the interval between the athlete leaving and returning to the mat. 
  • A linear position transducer that tracks the vertical displacement and velocity of a point on the athlete (typically a belt around the waist) using a cable. Can estimate countermovement depth, velocity, and jump height. 
  • A validated smartphone application that uses high-speed video to calculate jump height from flight time. 
  • A flat, non-slip surface with sufficient space for a full arm swing if that variant is used.

Conducting the test

As with most physical performance assessments, the athletes should warm up prior to the CMJ test. This should take approximately 5-10 minutes and include light jogging and dynamic stretching of the lower extremities, followed by a few submaximal attempts to allow subjects become familiar with the jumping technique.

  • Make sure the test is conducted in a well-lit space and the jumping surfaces have no obstructions.
  • Fix the arm condition for the test in advance (i.e., hands on hips or a free arm swing).
    • Hands on hips is recommended for isolating lower-body function. A free arm swing offers higher validity in sports where the arm swing is part of the skill itself.
  • Have the athlete stand quietly on the force platform, contact mat, or designated take-off point, feet approximately shoulder-width apart, for at least one second before starting.
  • Instruct the athlete to perform a rapid, continuous countermovement to a self-selected or pre-specified depth that is immediately followed by a maximal vertical jump, with no pause in between.
  • Give a standardized verbal cue. For example, a fixed count such as “3, 2, 1, jump”. Use the same tone, volume, and timing for every trial and every athlete.
  • Require the legs to remain extended in the air and the athlete to land in approximately the same location as take-off.
  • Avoid excessive knee flexion in preparation for landing where flight-time-based measurement is used.
  • Allow a minimum of 60 seconds of rest between trials to ensure adequate recovery.
  • Record at least three maximal trials, and use the average of these trials to monitor neuromuscular status over time.
  • Record the measurement method used alongside the result (i.e., force platform impulse-momentum, flight time, video-based, or another method).

If jump height is estimated from flight time rather than from a force platform’s impulse-momentum calculation, the following formula is used:

  • Jump height (m) = (g × t2) / 8, where g is gravitational acceleration (9.81 m/s2) and t is flight time in seconds. 

If mechanical work is measured instead of jump height, the power generated can be calculated using one of the following formulas:

  • The Lewis formula: average Power (Watts) = √4.9 x mass (kg) x √VJ (m) x 9.81.
  • The Sayers formula: peak power (W) = 60.7 x VJ (cm) + 45.3 x mass(kg) – 2055.
    • Note: this equation was derived from squat jump instead of countermovement jump data. However, applying CMJ data to the SJ-derived equation only produced a 2.7% overestimation.
  • The Johnson & Bahamonde formula: peak power (W) = 78.5 x VJ (cm) + 60.6 x mass (kg) -15.3 x height (cm) -1308.
    • Average power (W) = 41.4 x VJ (cm) + 31.2 x mass (kg) -13.9 x height (cm) + 431

This flight-time calculation rests on the assumption that the athlete leaves the ground and lands in the same body position, with fully extended hips, knees, and ankles at both take-off and touchdown. In practice, however, this assumption is frequently violated since athletes commonly flex their knees during landing preparation. This artificially extends flight time and inflates the calculated jump height. This is the main reason why flight-time-derived jump height and force-platform impulse-momentum jump height are not directly interchangeable, even when recorded simultaneously on the same jump.

Finally, the countermovement jump protocol does not have formalized age- and sex-based percentile tables for general use. However, some results exist for specific target groups, such as collegiate basketball players and track-and-field athletes.

Interpreting the results 

Reliability of the countermovement jump test is generally reported as good to excellent across different measurement systems. A recent study assessing countermovement depth and velocity found test-retest reliability of ICC = 0.809 to 0.900 for both force plates and linear position transducers (Li et al., 2025). When these systems were validated against motion capture, force plates showed a high to very high correlation (r = 0.894 to 0.937). Linear position transducers showed a somewhat lower, though still high, correlation (r = 0.721 to 0.726). This suggests linear position transducers can serve as an acceptable field alternative for athlete monitoring, but force plates remain preferable when precise quantification against standardized criteria is required. 

The reliability of derived force-time metrics is less consistent. A comparison of three commercial force plate systems (Vald ForceDecks, Hawkin Dynamics, and Sparta Science) found poor test-retest reliability for the reactive strength index modified and rate of force development, even though jump height itself showed relatively consistent agreement across systems (Merrigan et al., 2024). Consumer-grade tools such as smartphone applications and sports watches carry a small yet meaningful mean error against force platforms, typically in the low single-digit percentage range. The findings on systematic bias are mixed: some devices show none, while others show consistent under- or overestimation.

In practice, jump height is considered the most reliable metric of the countermovement jump test, while other force-time measurements should be used as supplementary data and interpreted with greater caution. Evidence also shows that measuring the average result of several test jumps provides a more thorough indication of an athlete’s neuromuscular status. As with any repeated-measures monitoring method, a change in CMJ height should be judged against the test’s own typical margin of error before being attributed to a change in performance. To ensure subsequent measurements remain valid, practitioners should aim to minimize the effect of any non-physiological factors. These include athlete motivation, verbal cueing consistency, familiarity with the movement, time of day, physical activity before the test, the arm-swing versus no-arm-swing, as well as countermovement depth.

The Best Sports Science eBooks Available.

Forget about overpriced online courses and expensive tuition fees. Our eBooks offer everything you need to know about athletic training.

Final thoughts

The countermovement jump test remains one of the most widely used field assessmentf for measuring lower-body neuromuscular power. The test is valued for its ease of administration, relatively low cost in comparison to other performance tests, as well as its long history of biomechanical validation going back to the original stretch-shortening cycle research of the 1970s and 1980s. However, its main strength lies in the wide selection of measurement systems available, ranging from laboratory-grade force platforms to inexpensive smartphone applications. Most of these report good-to-excellent reliability for jump height specifically. 

The main limitation of the countermovement jump test is the fact that different measurement methods, especially the flight-time method versus the force platform’s impulse-momentum method, are not interchangeable and can disagree by several centimetres even under controlled conditions. Consistency within one method and one setup is a reasonable basis for tracking change in an individual athlete, but comparing absolute values across different devices, protocols, or arm-swing conditions introduces a systematic error that should not be mistaken for a real physiological difference. When greater measurement precision or detailed force-time characteristics are required, a force platform still remains the reference standard. Where the stretch-shortening cycle characteristics of an athlete are of specific interest, reactive strength measures derived from a drop jump protocol may offer complementary information that the countermovement jump alone does not fully capture.

Did you learn anything new about the countermovement jump test? Let us know in the comments.

Bibliography

  • Asmussen, E., and Bonde-Petersen, F. (1974). Storage of elastic energy in skeletal muscles in man. Acta Physiologica Scandinavica. 
  • Balsalobre-Fernández, C., Glaister, M., and Lockey, R.A. (2015). The validity and reliability of an iPhone app for measuring vertical jump performance. Journal of Sports Sciences, 33(15), 1574-1579. 
  • Bosco, C., Luhtanen, P., and Komi, P.V. (1983). A simple method for measurement of mechanical power in jumping. European Journal of Applied Physiology and Occupational Physiology, 50(2), 273-282. 
  • Claudino, J.G., Cronin, J., Mezêncio, B., McMaster, D.T., McGuigan, M., Tricoli, V., Amadio, A.C., and Serrão, J.C. (2017). The countermovement jump to monitor neuromuscular status: a meta-analysis. Journal of Science and Medicine in Sport, 20(4), 397-402. Cohen, D.D., Burton, A., Wells, C., Taberner, M., Diaz, M.A., and Graham-
  • Harry, J.R., Barker, L.A., and Mercer, J.A. (2018). Relationships between countermovement jump ground reaction forces and jump height, reactive strength index, and jump time. Journal of Strength and Conditioning Research, 32(1), 248-254. 
  • Merrigan JJ, Strang A, Eckerle J, Mackowski N, Hierholzer K, Ray NT, Smith R, Hagen JA, Briggs RA. Countermovement Jump Force-Time Curve Analyses: Reliability and Comparability Across Force Plate Systems. J Strength Cond Res. 2024 Jan 1;38(1):30-37. doi: 10.1519/JSC.0000000000004586. Epub 2023 Oct 6. PMID: 37815253.
  • Sayers SP, Harackiewicz DV, Harman EA, Frykman PN, Rosenstein MT. Cross-validation of three jump power equations. Med Sci Sports Exerc. 1999 Apr;31(4):572-7. doi: 10.1097/00005768-199904000-00013. PMID: 10211854.
  • Schilling BK, Falvo MJ, Chiu LZ. Force-velocity, impulse-momentum relationships: implications for efficacy of purposefully slow resistance training. J Sports Sci Med. 2008 Jun 1;7(2):299-304. PMID: 24149464; PMCID: PMC3761460.
  • Smith, P. (2020). Concurrent validity of countermovement and squat jump height assessed with a contact mat and force platform in professional soccer players. 
  • Sole CJ, Suchomel TJ, Stone MH. Preliminary Scale of Reference Values for Evaluating Reactive Strength Index-Modified in Male and Female NCAA Division I Athletes. Sports (Basel). 2018 Oct 29;6(4):133. doi: 10.3390/sports6040133. PMID: 30380639; PMCID: PMC6315647.
  • Vieira A, Tufano JJ. Reactive strength index-modified: reliability, between group comparison, and relationship between its associated variables. Biol Sport. 2021 Sep;38(3):451-457. doi: 10.5114/biolsport.2021.100363. Epub 2020 Nov 4. PMID: 34475626; PMCID: PMC8329976.
  • Li Z, Ma W, Zhang L, Zhu W, Xie Q, Sun Y. The Validity and Reliability of the Force Plates and the Linear Position Transducer in Measuring Countermovement Depth and Velocity During Countermovement Jump. Sensors (Basel). 2025 Oct 23;25(21):6542. doi: 10.3390/s25216542. PMID: 41228765; PMCID: PMC12608286.

Join our growing list of subscribers!

Stay informed about the latest in sports science and physical performance. Subscribe to our mailing list for the latest updates, posts, products and much more.


    Daniel Kiikka

    Daniel Kiikka holds a Master’s Degree in sports science, with a focus on sports pedagogy. After graduating from the University of Jyväskylä in 2015, Daniel worked nearly a decade within the world-renowned Finnish educational system as a physical education and health science teacher. Since 2021, Daniel has worked as a Lecturer at the Amsterdam University of Applied Sciences.